Playground / Life cycle and circularity
Calculate the green, blue and grey water footprint of a farm’s crop with the Water Footprint Network method, follow it into a processed product, and check whether the catchment it draws on is a water hotspot.
Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use
New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.
Units: 1 mm of water over 1 hectare is 10 m³, and 1 m³ per tonne is the same as 1 litre per kilogram.
A sample is filled in so you see a result straight away: a fictional 2-hectare wheat farm in Punjab, India, whose wheat is milled into white flour. The weather and farm numbers are illustrative, chosen to look like a dry winter (rabi) season. November and April are part-months (sowing in mid-November, harvest in mid-April), so their ETo is lower than a full month. Change any number; the result updates as you type.
A water footprint measures the fresh water used to make a product, counted over its whole supply chain. The method was developed by Arjen Hoekstra and colleagues and is maintained by the Water Footprint Network (WFN), a non-profit network based in the Netherlands. Its standard is The Water Footprint Assessment Manual: Setting the Global Standard (2011), with Tier 1 guidelines for grey water added in 2013. They are still the versions in use in November 2026; the WFN remains active and is holding a session on financed water accounting at the UN Water Conference in the UAE in December 2026.
A full assessment has four phases: set the goal and scope, account the footprint, assess its sustainability, and plan responses. This tool covers accounting for a crop and one or two processing steps, and a simple sustainability check of one month in one catchment.
A different standard: ISO 14046:2014 sets out a life-cycle-based water footprint that weights water by local scarcity (for example with the AWARE method, updated to AWARE2.0 in 2025) and adds other water impacts. The two approaches give different numbers and should not be mixed. ISO 14046:2014 remains the current edition; check ISO’s page for the status of its periodic review.
What this tool leaves out: daily soil water balances (it uses the “crop water requirement” option, which assumes the crop is never short of water), water lost from reservoirs and canals before it reaches the field, Tier 2 and 3 pollution models, social and economic sustainability, and the supply chain beyond the farm and factory.
All results are in m³ per tonne, which equals litres per kilogram. Worked numbers come from the Manual’s own example (sugar beet in Valladolid, Spain, Appendices II and III) and the sample wheat farm.
| Step | Formula | Worked example | Source |
|---|---|---|---|
| Crop water need | ETc = Kc × ETo (mm per period) | Wheat, February: 1.15 × 80 mm = 92 mm | FAO Irrigation and Drainage Paper 56; Manual eq. 62 |
| Effective rain | USDA SCS, monthly: P ≤ 250 mm: P × (125 − 0.2 P) ÷ 125; P > 250 mm: 125 + 0.1 P | February 32 mm rain → 30.4 mm effective | Recommended by Smith (1992) and used in the Manual’s Appendix II (CROPWAT) |
| Green and blue ET | Each period: green = min(ETc, effective rain); blue = max(0, ETc − effective rain); then add the periods | Manual Table II.2: 18 ten-day periods give green 168 mm, blue 628 mm | Manual Appendix II, eqs 63 and 64, Table II.2 |
| Crop water use | CWU (m³/ha) = 10 × ET (mm) | 168 mm → 1,680 m³/ha green | Manual eqs 12, 13 |
| Green and blue water footprint | WF = CWU ÷ yield (t/ha) | Irrigation schedule option: 1,250 ÷ 81 = 15 m³/t green; 6,680 ÷ 81 = 82 m³/t blue | Manual eqs 9, 10; Table II.5 |
| Grey water footprint (diffuse) | WF = (α × application rate) ÷ (cmax − cnat) ÷ yield; keep the critical (largest) pollutant only | 0.1 × 178 kg N/ha ÷ 0.010 kg/m³ = 1,780 m³/ha; ÷ 81 t = 22 m³/t | Manual eq. 11, Table II.6; leaching fractions from the 2013 Tier 1 guidelines, Table 1 |
| Grey water footprint (pesticide, Tier 1) | Load = leaching-run-off fraction × amount applied; ÷ (cmax − cnat); ÷ production | Endosulfan on a Gujarat cotton farm: 0.046 × 0.003 t = 0.00014 t; ÷ 3 × 10⁻¹² t/m³ = 46 million m³; ÷ 1.2 t = 38 million m³/t | Franke and others (2013), Appendix IV |
| Grey water footprint (factory) | (effluent × c effluent − intake × c intake) ÷ (cmax − cnat); a negative load counts as 0 | (0.09 × 15 − 0.10 × 1) ÷ (10 − 0.5) = 0.13 m³/s | Manual eq. 4, Appendix IV example 1 |
| Product water footprint | (process WF + crop WF ÷ product fraction) × value fraction | Raw sugar blue: 82.5 ÷ 0.14 × 0.89 = 524 m³/t; refined: 524 ÷ 0.92 × 1 = 570 m³/t. Total refined sugar 107 + 570 + 152 = 829 m³/t | Manual eq. 15, Appendix III, Table III.1 |
| Value fraction | (fraction × price of the product) ÷ Σ (fraction × price) over all products | Flour 0.72 × 32 ÷ (0.72 × 32 + 0.26 × 20) = 0.816 (illustrative prices) | Manual eq. 69 |
| Blue water scarcity | Natural run-off = actual run-off + blue WF; available = natural × (1 − 80%); scarcity = blue WF of the catchment ÷ available | 30 ÷ ((40 + 30) × 0.2) = 214%: severe | Manual eq. 54; Hoekstra and others (2012) for the 80% default and classes |
| Water pollution level | Grey WF of the catchment ÷ actual run-off; above 100% breaks the standard | 12 ÷ 40 = 30% | Manual eq. 55 |
| World averages | Global average per tonne, 1996–2005 (green + blue + grey) | Wheat 1,277 + 342 + 207; maize 947 + 81 + 194; rice 1,146 + 341 + 187 | Mekonnen and Hoekstra (2011), Table 3 |
Work out the green, blue and grey water footprint of a fictional farm’s crop and of the product made from it, then judge the water scarcity and pollution level of its catchment.
Checked against the sources below in November 2026. Rules change: always use the official text for real work.
Rain that a crop uses could have fed a forest, another crop or a river. Green water shows how much of that land’s rain a product takes. It is usually less harmful than blue water, which is why the three colours are reported separately and not only as a total.
No. Only water that evaporates, goes into the product or leaves the catchment counts. Water that seeps back into the aquifer or flows back to the river can be used again downstream. The pumped amount (water withdrawal) is usually larger than the blue water footprint.
It shows how much clean water is needed to absorb the pollution. Where there is not enough water to dilute it, the river breaks its quality standard. The Manual counts only the critical pollutant, so that the same water is not counted twice for two pollutants.
Company frameworks such as GRI 303 and the EU’s ESRS E3 report the water a company withdraws, discharges and consumes at its own sites (the European Commission adopted revised, simplified ESRS on 3 July 2026; they apply once the Parliament and Council scrutiny period ends and the act is published in the Official Journal). A water footprint covers green, blue and grey water along the supply chain and is usually dominated by farming, not the factory.
They answer different questions. The Water Footprint Network method gives volumes of green, blue and grey water and judges them against local availability. ISO 14046 is a life-cycle assessment standard that turns water use into impact scores, often by weighting it with a scarcity factor such as AWARE. State which one you used and do not compare numbers across them.
No. You need a free account only to save results or take the graded case.
No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.