Skip to content
Sigma EarthPlayground

Playground / Carbon accounting

Organisational inventory

Practise the decisions behind an ISO 14064-1 greenhouse gas inventory: which facilities count and how much, which indirect categories are significant, which base year to use, and when that base year must be recalculated.

Free to use ISO 14064-1:2018 (confirmed 2024; revision under way) Advanced Global Verified credential available
Advertisement

Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use

New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.

How to use this tool · 8 short steps

  1. Read the sample: a fictional textile company with five facilities is filled in, and its result shows on the right (below the inputs on a phone).
  2. Step 1, Boundary: switch the consolidation approach between operational control, financial control and equity share, and watch how much of the joint-venture warehouse is counted.
  3. Step 2, Categories: set your magnitude criterion, tick influence, risk or stakeholder needs, and see which indirect categories become significant. Try leaving one out without a reason.
  4. Step 3, Base year: name the base year and untick a selection condition to see what the standard expects.
  5. Step 4, Recalculate: the acquisition and the sale come from step 1. Change the threshold, the method change or the error, and see when the base year must be restated.
  6. In step 1, open the acquired mill (facility 4) and change it to “built after the base year”, or the closed unit to “sold”, and compare the result. This is the heart of the tool.
  7. Step 5, Report: read the inventory by category, the base-year statement and the checklist of required report items.
  8. Save to My Playground, download a CSV or copy a summary. Then try the graded case.

Enter each facility’s whole emissions (100%); the tool applies your share. Base-year and this-year figures cover Categories 1 and 2 only.

Build your inventory

A fictional textile company is filled in so a result shows straight away. Work through the five steps and change anything. Results update as you type.

Step 1. Organisational boundary

First decide which facilities belong to the inventory, and how much of each. ISO 14064-1 calls this the organisational boundary. You pick one consolidation approach and use it for every facility and every year.

t CO₂e = tonnes of carbon dioxide equivalent: all greenhouse gases converted to the warming effect of CO₂.

One 12-month period for every figure.
What does this mean? It is the rule for how much of each site’s emissions belongs to you. Operational control: 100% of facilities you run, 0% of the rest. Financial control: 100% of facilities whose financial policies you direct; where control is shared, your ownership share (GHG Protocol practice). Equity share: your ownership percentage of every facility.

See what is counted for each facility
What your approach counts this year
FacilityShare countedThis year (t CO₂e)Since the base year

Open a facility to change it. Enter its whole emissions (100%); the tool applies your share. Category 1 = its own fuel, process and leak emissions; Category 2 = electricity, heat or steam it buys. For a sold or closed facility, enter the ownership and control it had while it was yours.

Facility 1: Pune main plant · Ours in both years
%
t CO₂e
The facility’s emissions in the base year, even if it belonged to someone else then. Leave 0 if it did not exist.
t CO₂e
t CO₂e

Facility 2: Nashik dyeing unit · Closed by us
%
t CO₂e
t CO₂e
t CO₂e

Facility 3: Kandla warehouse (joint venture) · Ours in both years
%
t CO₂e
t CO₂e
t CO₂e

Facility 4: Surat weaving mill · Bought; it existed in the base year
%
t CO₂e
t CO₂e
t CO₂e

Facility 5: Chennai finishing unit · Sold
%
t CO₂e
t CO₂e
t CO₂e

Advertisement

Quick facts

What it teaches
ISO 14064-1:2018 (confirmed 2024; revision under way)
Level
Advanced · no prior experience needed to try it
Where it applies
Global
Cost
Free to use. Optional verified credential after you pass the graded case: US$10, or ₹999 in India
Last checked
November 2026, against the official sources listed below
Use
Learning and practice only, not for real reporting

About ISO 14064-1

ISO 14064-1 is the international standard for how an organisation quantifies and reports its greenhouse gas (GHG) emissions and removals. The edition in force is ISO 14064-1:2018 (second edition, December 2018), confirmed by ISO’s five-year review in 2024. Companies, public bodies and universities use it, often with third-party verification under ISO 14064-3.

The standard asks the organisation to:

  • set an organisational boundary by control (financial or operational) or equity share;
  • set a reporting boundary: direct emissions (Category 1) plus the indirect emissions it judges significant under its own, explained criteria, sorted into Categories 2 to 6;
  • establish a base year with verifiable data, explain the choice, and keep a procedure for recalculating it after structural changes, changes of method or emission factor, or errors that add up to a substantial amount, but never for changes in production or the opening and closing of facilities.

The six categories differ from the GHG Protocol’s three scopes: Category 1 matches Scope 1, Category 2 matches Scope 2 (location-based), and Categories 3 to 6 regroup Scope 3.

What is changing: ISO marked the 2018 edition “to be revised”. A third edition is at working-draft stage (its latest comment period closed in May 2026). In July 2026 ISO and the GHG Protocol agreed to merge their corporate standards into one co-branded standard, with a joint public consultation planned for the second quarter of 2027 and publication planned for late 2028. Until then, the 2018 edition applies, and this tool follows it.

What this tool leaves out: splitting direct emissions by gas, biogenic CO₂, removals, uncertainty, verification, and the actual calculation of each category (see the GHG Scope 1 & 2 and Scope 3 tools). It tracks the base year for Categories 1 and 2 only.

How this is calculated

All figures are t CO₂e. Worked numbers use the sample company with operational control.

StepRule usedSample workingBasis
Share of a facilityOperational control: 100% if you run it, else 0%. Financial control: 100% if you direct its financial policies, your ownership % if that control is joint, else 0%. Equity share: ownership %Joint-venture warehouse (40%, run by the partner, joint financial control): 0% under operational control, 40% under the other twoISO 14064-1:2018 5.1 and Annex A; joint control by equity share from the GHG Protocol Corporate Standard ch. 3
Base year as first reportedΣ share × base-year emissions of facilities that were in the organisation in the base year (still owned, since sold, or since closed)12,000 + 2,400 (closed unit) + 1,500 (sold unit) = 15,900ISO 14064-1 6.4.1
Structural changesAcquired facility that existed in the base year: + share × its base-year emissions. Sold facility: − share × its base-year emissions. Facility that did not exist in the base year: no changeSurat mill +3,000; Chennai unit −1,500ISO 14064-1 6.4.2 a); GHG Protocol ch. 5, Figures 6–8
Other triggersChange of method or emission factor, and errors found: their effect on the base-year inventoryGrid factor −450; meter error +120ISO 14064-1 6.4.2 b) and c)
Not a triggerChanges in production, and opening or closing your own facilities: the base year is not changedNashik unit closed: stays in the base year, so its 2,400 t counts as a real reductionISO 14064-1 6.4.2
Significance testSize = Σ |each effect| (or |net effect| if chosen). Recalculate if size ÷ base year as first reported ≥ your threshold5,070 ÷ 15,900 = 31.9% ≥ 5%, so recalculateThreshold chosen by the organisation (some programmes use 10%); 5% per scope in the Science Based Targets initiative (SBTi) Corporate Net-Zero Standard (CNZS) V2.0
Simplification: one test for Categories 1 and 2This tool applies the threshold to Categories 1 and 2 added together. SBTi (from 1 February 2027, when V2.0 takes effect) and the GHG Protocol working group proposals test each scope separately, so a change could pass here and still trigger a recalculation for one scopeSample: all changes are Category 1 and 2 changes taken togetherSBTi CNZS V2.0 section 2.6; GHG Protocol TWG Subgroup 1, meeting 14 (June 2026, proposal)
Recalculated base yearBase year as first reported + net effect of all changes15,900 + 3,000 − 1,500 − 450 + 120 = 17,070ISO 14064-1 6.4.2
Change against base year(this year − base year used) ÷ base year used × 100(16,300 − 17,070) ÷ 17,070 = −4.5%. Against the unadjusted base year it would read +2.5%Like-with-like comparison
Significant indirect categorySignificant if its screening estimate ≥ your magnitude % of the screened total (Categories 1–6), or if you tick influence, risk or opportunity, or user requirementCategory 4: 9,800 ÷ 29,860 = 32.8% ≥ 5%, included. Category 5: 3.7%, not includedISO 14064-1 5.2.3 and Annex H (criteria are the organisation’s own)
Graded case

Prove you can apply it

Choose a fictional company’s base year, consolidate its facilities, decide whether acquisitions, sales and corrections force a recalculation, and select its significant indirect categories.

  • New numbers on every attempt
  • Answers checked against a tolerance
  • Up to 10 attempts a day, all free
Start the graded case
Verified learning credential US$10 ₹999 in India Public verification page, PDF with QR code, and a LinkedIn add. Pay only after you pass. A learning credential, not a professional certification.

Sources and rules used

Checked against the sources below in November 2026. Rules change: always use the official text for real work.

Questions about this tool

How do ISO 14064-1 categories relate to Scopes 1, 2 and 3?

Category 1 (direct emissions) matches Scope 1. Category 2 (imported energy) matches Scope 2 on a location-based basis. Categories 3 to 6 split what the GHG Protocol calls Scope 3 into transport, products the organisation uses, use of its products, and other sources. The two map onto each other closely, and ISO and the GHG Protocol are now merging their corporate standards, but ISO 14064-1:2018 does not itself declare a GHG Protocol inventory conformant.

Why is a closed factory not removed from the base year, when a sold one is?

Selling a factory moves its emissions to the buyer; nothing changes for the atmosphere, so the base year is adjusted to compare like with like. Closing your own factory really removes emissions, so it is kept in the base year and shows up as a reduction. The same logic applies to production going up or down.

What significance threshold should I use?

ISO 14064-1 does not set a number for either test: you define your own criteria and explain them. For base-year recalculation, 5% is common, and SBTi’s Corporate Net-Zero Standard V2.0 (released June 2026, in force from 1 February 2027) requires 5% for each scope separately. The GHG Protocol’s working group has proposed a recommended 5% threshold in its revision, but nothing is final.

Can I use certificates or green tariffs in Category 2?

ISO 14064-1:2018 requires imported electricity to be quantified location-based, with the grid-average factor. A market-based figure from certificates that meet quality criteria may be reported separately, as extra information.

What about a facility bought halfway through the year?

GHG Protocol guidance is to recalculate the base year for the whole year, and to count the facility for the whole current year too, so the two stay consistent. ISO 14064-1 leaves the detail to your recalculation procedure; this tool counts acquired facilities for the full year.

Do I need an account?

No. You need a free account only to save results or take the graded case.

Can I use this tool for my company’s reporting?

No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.