Playground / Carbon accounting
Practise the decisions behind an ISO 14064-1 greenhouse gas inventory: which facilities count and how much, which indirect categories are significant, which base year to use, and when that base year must be recalculated.
Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use
New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.
Enter each facility’s whole emissions (100%); the tool applies your share. Base-year and this-year figures cover Categories 1 and 2 only.
A fictional textile company is filled in so a result shows straight away. Work through the five steps and change anything. Results update as you type.
ISO 14064-1 is the international standard for how an organisation quantifies and reports its greenhouse gas (GHG) emissions and removals. The edition in force is ISO 14064-1:2018 (second edition, December 2018), confirmed by ISO’s five-year review in 2024. Companies, public bodies and universities use it, often with third-party verification under ISO 14064-3.
The standard asks the organisation to:
The six categories differ from the GHG Protocol’s three scopes: Category 1 matches Scope 1, Category 2 matches Scope 2 (location-based), and Categories 3 to 6 regroup Scope 3.
What is changing: ISO marked the 2018 edition “to be revised”. A third edition is at working-draft stage (its latest comment period closed in May 2026). In July 2026 ISO and the GHG Protocol agreed to merge their corporate standards into one co-branded standard, with a joint public consultation planned for the second quarter of 2027 and publication planned for late 2028. Until then, the 2018 edition applies, and this tool follows it.
What this tool leaves out: splitting direct emissions by gas, biogenic CO₂, removals, uncertainty, verification, and the actual calculation of each category (see the GHG Scope 1 & 2 and Scope 3 tools). It tracks the base year for Categories 1 and 2 only.
All figures are t CO₂e. Worked numbers use the sample company with operational control.
| Step | Rule used | Sample working | Basis |
|---|---|---|---|
| Share of a facility | Operational control: 100% if you run it, else 0%. Financial control: 100% if you direct its financial policies, your ownership % if that control is joint, else 0%. Equity share: ownership % | Joint-venture warehouse (40%, run by the partner, joint financial control): 0% under operational control, 40% under the other two | ISO 14064-1:2018 5.1 and Annex A; joint control by equity share from the GHG Protocol Corporate Standard ch. 3 |
| Base year as first reported | Σ share × base-year emissions of facilities that were in the organisation in the base year (still owned, since sold, or since closed) | 12,000 + 2,400 (closed unit) + 1,500 (sold unit) = 15,900 | ISO 14064-1 6.4.1 |
| Structural changes | Acquired facility that existed in the base year: + share × its base-year emissions. Sold facility: − share × its base-year emissions. Facility that did not exist in the base year: no change | Surat mill +3,000; Chennai unit −1,500 | ISO 14064-1 6.4.2 a); GHG Protocol ch. 5, Figures 6–8 |
| Other triggers | Change of method or emission factor, and errors found: their effect on the base-year inventory | Grid factor −450; meter error +120 | ISO 14064-1 6.4.2 b) and c) |
| Not a trigger | Changes in production, and opening or closing your own facilities: the base year is not changed | Nashik unit closed: stays in the base year, so its 2,400 t counts as a real reduction | ISO 14064-1 6.4.2 |
| Significance test | Size = Σ |each effect| (or |net effect| if chosen). Recalculate if size ÷ base year as first reported ≥ your threshold | 5,070 ÷ 15,900 = 31.9% ≥ 5%, so recalculate | Threshold chosen by the organisation (some programmes use 10%); 5% per scope in the Science Based Targets initiative (SBTi) Corporate Net-Zero Standard (CNZS) V2.0 |
| Simplification: one test for Categories 1 and 2 | This tool applies the threshold to Categories 1 and 2 added together. SBTi (from 1 February 2027, when V2.0 takes effect) and the GHG Protocol working group proposals test each scope separately, so a change could pass here and still trigger a recalculation for one scope | Sample: all changes are Category 1 and 2 changes taken together | SBTi CNZS V2.0 section 2.6; GHG Protocol TWG Subgroup 1, meeting 14 (June 2026, proposal) |
| Recalculated base year | Base year as first reported + net effect of all changes | 15,900 + 3,000 − 1,500 − 450 + 120 = 17,070 | ISO 14064-1 6.4.2 |
| Change against base year | (this year − base year used) ÷ base year used × 100 | (16,300 − 17,070) ÷ 17,070 = −4.5%. Against the unadjusted base year it would read +2.5% | Like-with-like comparison |
| Significant indirect category | Significant if its screening estimate ≥ your magnitude % of the screened total (Categories 1–6), or if you tick influence, risk or opportunity, or user requirement | Category 4: 9,800 ÷ 29,860 = 32.8% ≥ 5%, included. Category 5: 3.7%, not included | ISO 14064-1 5.2.3 and Annex H (criteria are the organisation’s own) |
Choose a fictional company’s base year, consolidate its facilities, decide whether acquisitions, sales and corrections force a recalculation, and select its significant indirect categories.
Checked against the sources below in November 2026. Rules change: always use the official text for real work.
Category 1 (direct emissions) matches Scope 1. Category 2 (imported energy) matches Scope 2 on a location-based basis. Categories 3 to 6 split what the GHG Protocol calls Scope 3 into transport, products the organisation uses, use of its products, and other sources. The two map onto each other closely, and ISO and the GHG Protocol are now merging their corporate standards, but ISO 14064-1:2018 does not itself declare a GHG Protocol inventory conformant.
Selling a factory moves its emissions to the buyer; nothing changes for the atmosphere, so the base year is adjusted to compare like with like. Closing your own factory really removes emissions, so it is kept in the base year and shows up as a reduction. The same logic applies to production going up or down.
ISO 14064-1 does not set a number for either test: you define your own criteria and explain them. For base-year recalculation, 5% is common, and SBTi’s Corporate Net-Zero Standard V2.0 (released June 2026, in force from 1 February 2027) requires 5% for each scope separately. The GHG Protocol’s working group has proposed a recommended 5% threshold in its revision, but nothing is final.
ISO 14064-1:2018 requires imported electricity to be quantified location-based, with the grid-average factor. A market-based figure from certificates that meet quality criteria may be reported separately, as extra information.
GHG Protocol guidance is to recalculate the base year for the whole year, and to count the facility for the whole current year too, so the two stay consistent. ISO 14064-1 leaves the detail to your recalculation procedure; this tool counts acquired facilities for the full year.
No. You need a free account only to save results or take the graded case.