Playground / Energy and buildings
Compare what a home would pay and emit in a year with a heat pump instead of a gas, LPG or oil boiler, using your country’s prices and electricity grid, and find the efficiency a heat pump needs to win.
Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use
New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.
Your yearly fuel use is on your bills or your supplier’s app. If you only have one month, multiply a winter month by 4 and a summer month by 2 for a rough year: or simply use the sample.
A sample home in Great Britain is filled in so you see a result straight away. Work through the four steps and change any number. Results update as you type.
A boiler burns fuel to heat water for radiators and taps. A heat pump uses electricity to move heat from the outside air (or ground) into the home, so it delivers more heat than the electricity it uses. Its efficiency over a year is rated in a lab as the SCOP (seasonal coefficient of performance) and measured in homes as the SPF (seasonal performance factor); this tool calls both SCOP. Lab ratings are usually higher than what homes achieve: the UK government’s Electrification of Heat trial measured a median SPF of 2.80 for air source heat pumps in real homes.
Whether a heat pump is cheaper and cleaner depends on three numbers: the SCOP, the price of electricity compared with the fuel, and how much CO₂e (carbon dioxide equivalent: all greenhouse gases counted as CO₂) the electricity grid emits per kWh. This tool shows the break-even SCOP for each, the way energy advisers and installers reason about it. There is no single official standard for this comparison; in the UK, certified installers (Microgeneration Certification Scheme, MCS) must give a written performance estimate before a sale (standard MCS 031). The tool uses official emission factors (mostly from the UK Department for Energy Security and Net Zero, DESNZ) and published prices.
What has changed recently: in Great Britain the price cap rose 26% for January to March 2027, VAT was removed from electricity bills from 1 October 2026 to 30 June 2027 (Ofgem), and Ofgem cut its typical gas use from 11,500 to 9,500 kWh a year from 1 July 2026. The UK Boiler Upgrade Scheme gives £7,500 (£9,000 for homes leaving heating oil, from 21 July 2026). In the US the federal 25C heat pump tax credit ended after 31 December 2025. In the EU, subsidies for stand-alone fossil boilers stopped from 1 January 2025, and the new carbon price on heating fuels (ETS2) was moved from 2027 to 2028. Prices change every few months, so treat every figure as a snapshot.
What this tool leaves out: heat-loss calculations and sizing, hourly weather, time-of-use tariffs, solar panels, hybrid systems, maintenance, upstream fuel supply, grid losses, refrigerant leaks and the emissions of making the equipment. It is a learning estimate, not advice on buying a heating system.
An energy balance: the heat the home needs is the same for both systems. Worked numbers use the sample home (9,500 kWh of gas, 85% boiler, SCOP 2.8, Great Britain prices for January to March 2027).
| Step | Formula | Factor or price used | Source |
|---|---|---|---|
| Heat the home needs | fuel kWh × boiler efficiency. Sample: 9,500 × 85% = 8,075 kWh | Field trial of 60 condensing boilers: 82.5% (combi) and 85.3% (regular) in real homes; England requires ≥92% rated efficiency for new gas boilers | Energy Saving Trust in-situ trial for DECC (2009); Boiler Plus (2018) |
| Fuel units to kWh | m³, litres, kg or therms × kWh per unit | Natural gas 11.115 kWh per m³; LPG 13.703 kWh per kg and 7.259 per litre; heating oil 10.294 kWh per litre (gross); 1 therm = 29.3071 kWh | Derived from DESNZ 2026 factors per unit ÷ per kWh, so both routes give the same CO₂e |
| Heat pump electricity | heat ÷ SCOP. Sample: 8,075 ÷ 2.8 = 2,884 kWh | Median seasonal performance factor (SPF H4, measured in homes) 2.80 for air source heat pumps, 742 systems; 2.44 on the coldest days. A datasheet SCOP (a lab rating under EN 14825) is usually higher | Electrification of Heat Demonstration Project, interim data (Energy Systems Catapult for DESNZ, 2023) |
| Boiler emissions | fuel kWh × factor. Sample: 9,500 × 0.18442 = 1,752 kg CO₂e | kg CO₂e per kWh (gross): natural gas 0.18442 (the “Natural gas (100% mineral blend)” row; the default UK row, 0.18231, includes biomethane in the UK grid), LPG 0.2145, heating oil 0.24677 | UK DESNZ GHG conversion factors 2026 (used here for every country) |
| Heat pump emissions | electricity kWh × grid factor. Sample: 2,884 × 0.13096 = 378 kg | UK 0.13096 kg CO₂e/kWh; US 0.34967; Germany 0.344 (CO₂ only, used as CO₂e; 2025 estimate); France 0.0196; India 0.675 (CO₂ only, used as CO₂e) | DESNZ 2026; EPA eGRID2023 (rev. 2, June 2025); Umweltbundesamt 2026; RTE Bilan électrique 2025; CEA v22.0 |
| Running cost | energy × unit price + standing charge × 365. Sample boiler: 9,500 × £0.1096 + £0.2965 × 365 = £1,149; heat pump: 2,884 × £0.3269 + £108 = £1,051 | GB price cap Jan–Mar 2027: electricity 32.69p/kWh (no VAT), gas 10.96p/kWh + 29.65p/day (5% VAT). US EIA 2025 (electricity 17.23 cents per kWh); Germany and France Eurostat 2026-S1; India LPG ₹942 per 14.2 kg | Ofgem; US EIA; Eurostat; Indian Oil prices as reported |
| Break-even SCOP, cost | heat × electricity price ÷ (fuel cost + standing charge saved). Without standing charges: price ratio × efficiency = 2.98 × 0.85 = 2.54 | Price ratio = electricity price ÷ fuel price per kWh | Energy balance (this tool) |
| Break-even SCOP, carbon | grid factor ÷ fuel factor × efficiency. Sample: 0.13096 ÷ 0.18442 × 0.85 = 0.60 | Below this SCOP the heat pump emits more than the boiler | Energy balance (this tool) |
| Payback (optional) | (heat pump cost − grant − boiler you would otherwise buy) ÷ yearly saving | Sample costs are illustrative; median UK air source install about £13,000 in 2025-26 | Boiler Upgrade Scheme statistics (DESNZ) as analysed by Nesta, 2026 |
Compare a boiler and a heat pump for a fictional household: heat demand, electricity use, emissions, running costs and the break-even efficiency.
Checked against the sources below in November 2026. Rules change: always use the official text for real work.
It depends on the price ratio. Divide the electricity price by the gas price per kWh and multiply by the boiler efficiency: that is the SCOP a heat pump needs to break even. With Great Britain’s January to March 2027 prices and an 85% boiler it is about 2.5, so a typical heat pump (SCOP around 2.8) is a little cheaper, and more so if the gas connection is removed.
Almost always where the grid is fairly clean. It wins on carbon when its SCOP is above grid factor ÷ fuel factor × boiler efficiency. In the UK or France that break-even is below 1, so any working heat pump wins. On a coal-heavy grid such as India’s it is about 2.7 against LPG, so a poorly performing heat pump can emit more.
In real homes, about 2.8: the UK’s Electrification of Heat trial measured a median seasonal performance factor of 2.80 for 742 air source heat pumps, and 2.44 on the coldest days. A datasheet SCOP is a lab rating at one flow temperature and is usually higher. Systems with low flow temperatures and correctly set weather compensation often do better.
It sets how much heat the home really uses. An inefficient boiler burns more fuel for the same heat, so replacing it saves more, and the heat pump looks better.
A fixed daily charge for having a gas or electricity supply. If a home removes its gas connection after fitting a heat pump, it stops paying the gas standing charge; the electricity one is paid either way.
No. You need a free account only to save results or take the graded case.
No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.