Playground / Energy and buildings
Practise a walk-through energy audit of a building: read 12 months of bills, work out energy use per square metre against a benchmark, split the energy into end uses and rank savings measures by simple payback.
Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use
New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.
Payback is in years: a measure that costs 100 and saves 50 a year pays back in 2 years.
A fictional office building is filled in so you can see a result straight away. Work through the five steps and change any number. Results update as you type.
An energy audit is a careful look at how a building or site uses energy, followed by a list of ways to use less, each with its saving, cost and payback. It usually runs in four stages: collect the bills and data, analyse them (patterns, a benchmark, an energy balance by end use), find and cost the savings measures, and report.
What this tool covers: a walk-through (Level 1-style) audit of one building: bill analysis, energy use intensity against a benchmark, an estimated end-use split, and up to eight measures ranked by simple payback with net present value. It leaves out measurements and sub-metering, weather correction, demand-charge savings, extra running costs, renewable energy options and measurement and verification of savings.
Worked numbers use the sample office (940,000 kWh of electricity a year). The sample savings percentages, costs, lives and prices are illustrative values for learning, not published figures.
| Step | Formula | Sample working | Source |
|---|---|---|---|
| Annual electricity | Sum of the 12 monthly bills (kWh) | 82,000 + 98,000 + … + 70,000 = 940,000 kWh | Utility bills (audit data collection) |
| Energy charge per kWh | (bill total − fixed and demand charges) ÷ kWh. Used to value every kWh saved. | (8,900,000 − 1,200,000) ÷ 940,000 = 8.19 per kWh; the average price would be 9.47 | Audit practice: savings are valued at the rate that changes with use |
| Fuel energy | quantity × gross calorific value | Diesel 12,000 litres × 10.563 kWh/litre = 126,756 kWh; LPG 1,500 kg × 13.703 kWh/kg = 20,555 kWh | UK DESNZ 2026: factor per unit ÷ factor per kWh (gross CV); diesel and natural gas use the 100% mineral rows (no biofuel or biomethane), whose CO₂ factors are 1–3% above the UK average-blend rows; 1 therm = 29.3071 kWh |
| Electricity per m² (EPI), compared with the BEE benchmark | electricity ÷ gross floor area | 940,000 ÷ 5,000 = 188 kWh/m² a year, 5% above the benchmark of 179 | BEE indicative EPI benchmarks for commercial buildings (UNDP-GEF-BEE study); BEE counts building electricity (grid and diesel-generator), not fuel energy |
| Site energy use intensity (EUI) | (electricity + fuel energy) ÷ gross floor area | (940,000 + 147,311) ÷ 5,000 = 217 kWh/m² a year. Fuel counts at its full energy content, so this is not compared with BEE’s electricity benchmark; an own benchmark is compared with it. | Energy balance method |
| Year-round (non-seasonal) share | lowest month × 12 ÷ annual electricity | 56,000 × 12 ÷ 940,000 = 71%: most of the load does not depend on the weather | Bill analysis |
| Measure saving | end-use kWh × saving %; money = kWh × energy charge (fuel measures: fuel cost × saving %) | LED: 940,000 × 20% × 50% = 94,000 kWh × 8.19 = 770,000 a year | Energy balance method |
| Simple payback | cost ÷ annual money saved | LED: 1,200,000 ÷ 770,000 = 1.6 years | BEE guide book, Performing financial analysis, section 11.4 |
| Net present value (NPV) | − cost + annual saving × (1 − (1 + r)^(−life)) ÷ r | LED at 8% over 10 years: −1,200,000 + 770,000 × 6.710 = 3,966,000 | BEE guide book, section 11.5; EU EED Annex VI(e) |
| Measures together | Applied in ranked order to what is left of each end use: combined share = 1 − (1 − a)(1 − b) | Sensors 25% then LED 50%: 1 − 0.75 × 0.5 = 62.5% of lighting, not 75% | Interactive effects (ASHRAE Standard 211 Level 2 practice) |
| Emissions avoided | electricity saved × grid factor + fuel saved × fuel factor | LED: 94,000 kWh × 0.675 t/MWh = 63.5 t CO₂ | CEA v22.0 (India); DESNZ 2026 (UK grid and fuels); EPA eGRID2023 (US) |
Audit a fictional building: analyse its bills, work out its energy use per m², value and rank four savings measures by payback and combine two that overlap.
Checked against the sources below in November 2026. Rules change: always use the official text for real work.
An energy audit studies how a building or site uses energy and lists ways to save it, each with its energy saving, cost and payback. It starts with a year of bills, adds a walk-through or measurements, and ends with a report of ranked measures.
Divide the cost of the measure by the money it saves each year. A measure that costs 1,200,000 and saves 770,000 a year pays back in about 1.6 years. Shorter is better, but payback ignores the savings after it and the time value of money, so audits also use net present value.
EUI is the energy a building uses in a year divided by its floor area, in kWh per square metre a year. It lets you compare buildings of different sizes with a benchmark for the same type of building and climate. In India the Bureau of Energy Efficiency’s benchmarks use the energy performance index (EPI), which counts building electricity (grid and diesel-generator) per m², so compare them with electricity use, not fuel energy.
The second measure works on the energy the first one left. If LED lights save 50% and sensors 25%, together they save 1 − 0.5 × 0.75 = 62.5% of lighting energy, not 75%. Adding separate savings counts some kWh twice.
It depends on the country. In the EU, enterprises using more than 10 TJ a year must have one at least every four years (first by 11 October 2026). In the UK, large undertakings must comply with ESOS phase 4 by 5 December 2027. In India, BEE can require designated consumers to use accredited energy auditors.
No. You need a free account only to save results or take the graded case.
No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.