Skip to content
Sigma EarthPlayground

Playground / Carbon markets and regulation

Carbon credit project

Work out how many carbon credits a practice clean-cooking project could earn: baseline emissions from wood fires, project emissions from the new stoves, the methodology’s deductions, and what a buyer finally receives.

Free to use Verra VCS (VM0050 v1.0, VCS Standard v5.0) and Gold Standard, with ICVCM CCP conditions Advanced Global Verified credential available
Advertisement

Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use

New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.

How to use this tool · 5 short steps

  1. Look at the sample first: 10,000 improved wood stoves in a fictional village programme are filled in, and the credits show on the right (below the steps on a phone).
  2. Step 1: say how many stoves are in use and how that was measured (a survey result is capped at 90% or 75%), and check whether the project counts as additional (would it happen without carbon money?).
  3. Step 2: describe cooking before the project. The share of wood that is non-renewable (fNRB) is the number that matters most, so try changing it.
  4. Step 3: describe the new stoves. The tool checks for stove stacking (families still using the old fire) and caps the baseline if needed.
  5. Step 4: see the credits, the five-year forecast and whether the credits could carry a high-integrity CCP label. Then download your practice report or try the graded case.

Every number you type updates the result straight away. Use the “Reset to the sample numbers” button to start again.

Estimate your project’s credits

A sample clean-cooking project is filled in so you see a result straight away. Work through the four steps and change any number. Results update as you type.

Step 1. The project

The sample project gives households a better stove so they burn less wood. Fewer trees are cut, so less carbon dioxide (CO₂) reaches the air. A carbon credit counts one tonne of CO₂-equivalent (t CO₂e) avoided.

Working it out…

The vintage is the year the emissions were avoided. It matters for the CCP label rules in step 4.
stoves
Count every stove commissioned (installed and working). Example: 10,000.
%
Example: 85 means 85 of every 100 stoves are still used. A survey result may be capped: see the next question.
What does this mean? Verra caps a survey at 90% if the project gives all three kinds of support (stoves that suit local cooking, training in the local language, a free helpline), otherwise at 75%. Monitors are not capped.
Changing this also sets a typical efficiency in step 3.
Is the project additional? (Would it happen without carbon money?)

Advertisement

Quick facts

What it teaches
Verra VCS (VM0050 v1.0, VCS Standard v5.0) and Gold Standard, with ICVCM CCP conditions
Level
Advanced · no prior experience needed to try it
Where it applies
Global
Cost
Free to use. Optional verified credential after you pass the graded case: US$10, or ₹999 in India
Last checked
November 2026, against the official sources listed below
Use
Learning and practice only, not for real reporting

About carbon credit projects, Verra and Gold Standard

A carbon credit stands for one tonne of carbon dioxide equivalent (t CO₂e) that a project avoided or removed, compared with what would have happened without it (the baseline). Independent programmes write the rules: Verra runs the Verified Carbon Standard (VCS) and issues Verified Carbon Units (VCUs); Gold Standard issues Gold Standard Verified Emission Reductions. Each project follows an approved methodology and is checked by an independent auditor before credits are issued.

This tool uses Verra’s cookstove methodology VM0050 v1.0 (October 2024). Cookstoves are a big part of the market and were heavily criticised: a 2024 study in Nature Sustainability estimated that older cookstove methods issued about ten times more credits than the real reduction. VM0050 tightened the rules: measured fuel use, a stove-stacking cap, caps on survey-based usage rates (added by Verra’s clarifications of February 2025) and a 5% deduction for leakage. In 2025 the Integrity Council for the Voluntary Carbon Market (ICVCM) approved VM0050 for its Core Carbon Principles (CCP) label, with conditions.

What is changing: Verra released VCS Version 5 on 16 December 2025; in October 2026 it moved most effective dates from 1 January to 1 July 2027. Version 5 shortens energy crediting periods to 5 years, renewable twice, for new projects registering after 1 July 2027. VM0050 v1.0 accepts three fNRB sources: the UNFCCC national default value, the CDM TOOL33 default, or the project’s own CDM TOOL30 calculation with a 26% discount. A major revision, VM0050 v2.0, was consulted on in July–August 2026 and is not final; it would add the MoFuSS-DS tool for fNRB and remove TOOL30. Gold Standard runs its own cookstove methodologies; a CCP-labelled Gold Standard cookstove project announced in November 2026 uses fNRB derived from the MoFuSS model. Grid-connected solar and wind credits under the old CDM methods (ACM0002, AMS-I.D) were refused the CCP label in 2024; Verra’s replacement VMR0017 was approved in 2026.

What this tool leaves out: charcoal and renewable-biomass fuels, sampling precision, efficiency loss with age, fuel transport, LPG upstream emissions and the forest and soil (AFOLU) projects that need a buffer pool. It is a learning estimate, not a project design.

How this is calculated

Everything is worked out per household first, then multiplied by the stoves still in use. Worked numbers use the sample: 10,000 improved wood stoves, 85% in use, households of 4 adult equivalents, fNRB 30% (an illustrative value).

StepFormulaValues usedSource
Baseline fuel per householdDefault: 0.5 t wood per adult equivalent per year × household size; or a measured Kitchen Performance Test (KPT) value. Sample: 0.5 × 4 = 2.0 t0.5 t/person/year of air-dried woodVM0050 v1.0, section 8.1.1 and parameter BCex-ante
Baseline energy (ECᵢ)fuel (t) × net calorific value. Sample: 2.0 × 0.0156 = 0.0312 TJWood 0.0156 TJ/tVM0050, equation 2; IPCC 2006 Guidelines
Emission factor per TJ of wood112 × fNRB + 9.46. Sample: 112 × 0.30 + 9.46 = 43.06 t CO₂e/TJCO₂ 112 t/TJ (only the non-renewable share counts); CH₄ and N₂O 9.46 t CO₂e/TJ with AR5 GWPsVM0050 section 9.1; IPCC 2006 Vol. 2, Table 2.5; VCS Standard v5.0 (AR5)
fNRB from CDM TOOL30calculated value × (1 − 0.26). Example: 0.60 × 0.74 = 0.4426% uncertainty discountVM0050, parameter fNRB
Stove-stacking capECest = project energy × new efficiency ÷ old efficiency. If ECᵢ is larger, ECest is used. Sample: 1.1 × 0.0156 × 30 ÷ 15 = 0.0343 TJ, above 0.0312, so no capThree-stone fire 15% (default)VM0050, equation 3 and parameter ηold
Share in use (n)Measured by stove use monitors or meters: as measured. By survey: at most 90% (all three customer-support actions) or 75% (otherwise). Sample: 85%, from stove use monitors, so no capCaps 90% and 75%Verra, Corrections and clarifications to VM0050 v1.0 (3 February 2025), clarification 2
Baseline emissions (BE)energy used × stoves × share in use × factor. Sample: 0.0312 × 10,000 × 0.85 × 43.06 = 11,419.5 tVM0050, equation 1
Project emissions (PE)Wood stove: energy × factor above. LPG: kg ÷ 1,000 × 0.0473 TJ/t × 63.27 t CO₂e/TJ. Electric: MWh × grid factor × (1 + losses). Sample: 1.1 × 0.0156 × 8,500 × 43.06 = 6,280.7 tLPG: CO₂ 63.1 + CH₄/N₂O 0.1665 t CO₂e/TJVM0050, equations 7 and 8; IPCC 2006 Vol. 2, Tables 1.2, 1.4 and 2.5
Emission reductions (ER)(BE − PE) × 0.95. Sample: (11,419.5 − 6,280.7) × 0.95 = 4,881.8 t; 4,881 credits (whole tonnes only)0.95 covers leakage (non-project users, old stoves reused)VM0050, equation 11
Article 6.4 levies (option)5% of issued credits to the Adaptation Fund and 2% cancelled for overall mitigation (OMGE), each rounded to whole creditsShown only to compare routesDecision 3/CMA.3; UNFCCC note on fees and levies, 2026
Graded case

Prove you can apply it

Calculate the credits of a fictional clean-cooking programme with VM0050: the usage-rate cap, baseline energy, fNRB, the stove-stacking cap, emission reductions, additionality and the CCP label conditions.

  • New numbers on every attempt
  • Answers checked against a tolerance
  • Up to 10 attempts a day, all free
Start the graded case
Verified learning credential US$10 ₹999 in India Public verification page, PDF with QR code, and a LinkedIn add. Pay only after you pass. A learning credential, not a professional certification.

Sources and rules used

Checked against the sources below in November 2026. Rules change: always use the official text for real work.

Questions about this tool

How are carbon credits calculated for a cookstove project?

Credits = (baseline emissions − project emissions) × 0.95 under Verra’s VM0050. Baseline emissions come from the wood the old fires would have burned, counting only the non-renewable share of the wood (fNRB) for CO₂. Project emissions come from the fuel or electricity the new stoves use. The 0.95 deducts 5% for leakage.

What is fNRB and why does it matter so much?

fNRB is the fraction of non-renewable biomass: the share of the wood collected that is not regrowing. Only that share of the CO₂ counts, so halving fNRB roughly halves the credits. VM0050 v1.0 accepts the UNFCCC national default, the CDM TOOL33 default or an own CDM TOOL30 calculation (cut by 26%). For a CCP label, TOOL33 is accepted only for reductions up to 31 December 2025; later reductions need a MoFuSS-based value accepted in the approved project documents.

What is stove stacking?

Stove stacking means families keep using the old fire alongside the new stove. VM0050 checks it by working back from the energy the new stoves use. If the baseline is larger than that back-calculated value, the smaller value is used, so the project cannot claim savings from cooking the new stove never did.

Does a cookstove project need a buffer pool?

No. Verra’s pooled buffer accounts are for forest and land (AFOLU) and geological storage projects, whose stored carbon could be released later. A cookstove project avoids emissions, so it has no buffer; its main deduction is the 5% for leakage.

What is the difference between a VCU and a CCP-labelled credit?

A VCU is a credit issued by Verra. A CCP label is an extra tag the ICVCM allows on credits from approved methodologies when the project meets the stated conditions. For VM0050 those include the fNRB source and how fuel use was measured. Not every VCU carries the label.

Can a solar farm earn carbon credits?

Mostly no, for new projects. Verra limits grid-connected wind and solar to least developed countries by default, and the ICVCM refused the CCP label for the old renewable methods in 2024 because many projects would have been built anyway. Verra’s new VMR0017 was approved in 2026 for some countries.

Do I need an account?

No. You need a free account only to save results or take the graded case.

Can I use this tool for my company’s reporting?

No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.