Skip to content
Sigma EarthPlayground

Playground / Nature and environment

Air quality index

Type one day’s pollution readings and see how India’s National Air Quality Index (CPCB) and the US Air Quality Index (EPA) turn them into one number, a colour and a health message, and why the two scales give different numbers.

Free to use CPCB National Air Quality Index (2014 method, used since 2015) and US EPA AQI (40 CFR Part 58 Appendix G, 2024 update) Beginner India, US Verified credential available
Advertisement

Learning tool. This tool simplifies the official method and uses sample or default data. Do not use its results for business decisions, regulatory filings, assurance, investment or legal compliance. Framework and standard names belong to their owners; Sigma Earth is not affiliated with or endorsed by them. Terms of use

New here? Sample numbers are already filled in, so you can see a full result straight away. Change any number and the result updates by itself; nothing can break. You only need an account to save your work.

How to use this tool · 5 short steps

  1. Look at the sample result: one winter day in a fictional Indian city is filled in. The result is on the right, or below the steps on a phone.
  2. In step 1, change any reading. Leave a box empty if that pollutant was not measured. The line at the top of the step shows both indices as you type.
  3. In step 2, see how India gives each pollutant a sub-index, and why the highest one becomes the AQI.
  4. In step 3, add the 1-hour readings the US uses, and watch each reading get converted and truncated.
  5. In step 4, compare the two scales. Then save, download or copy your result, or try the graded case.

Real air quality data for Indian cities is on CPCB’s daily bulletin; US data is on AirNow. You can type a real day’s readings here to practise.

Work out the air quality index

A sample winter day in a fictional Indian city is filled in, so a result shows straight away. Go through the four steps and change any reading. Results update as you type.

Step 1. Your pollutant readings

An air quality index (AQI) turns several pollution readings into one number and one colour. Type one day’s readings in the units Indian stations report; leave a box empty if it was not measured.

Working it out…

Particles (dust, smoke and soot)

µg/m³
Particles under 2.5 micrometres. µg/m³ = micrograms per cubic metre of air. Example: 142.
µg/m³
Mostly road dust. Example: 268.

Gases

µg/m³
Mostly from vehicle exhausts. Example: 68.
µg/m³
From burning coal and oil. Example: 14.
mg/m³
Note: milligrams (1 mg = 1,000 µg). Example: 1.9.
µg/m³
Forms in sunlight; low in winter. Example: 38.
More options: place and day, ammonia, lead, data hours
µg/m³
From farming and fertiliser. India’s index includes it; the US index does not. Example: 32.
µg/m³
Measured from filter samples in a laboratory, so it is often missing. Example: 0.4. Empty in the sample.

Ammonia was not measured today. What goes in its box?

Advertisement

Quick facts

What it teaches
CPCB National Air Quality Index (2014 method, used since 2015) and US EPA AQI (40 CFR Part 58 Appendix G, 2024 update)
Level
Beginner · no prior experience needed to try it
Where it applies
India, US
Cost
Free to use. Optional verified credential after you pass the graded case: US$10, or ₹999 in India
Last checked
November 2026, against the official sources listed below
Use
Learning and practice only, not for real reporting

About air quality indices in India and the US

An air quality index (AQI) turns readings of several pollutants into one number, a colour and a health message. Each pollutant gets a sub-index by placing its concentration in a range; the highest sub-index is the AQI.

India: the National Air Quality Index of the Central Pollution Control Board (CPCB) was designed in 2014 and has been published since 2015. It covers eight pollutants (PM10, PM2.5, NO₂, SO₂, CO, ozone, ammonia and lead) with six categories from Good to Severe, and runs from 0 to 500. An index of 100 matches India’s short-term National Ambient Air Quality Standards of 2009. CPCB’s minimum-data rules for an index: at least three pollutants, one of them PM2.5 or PM10, and at least 16 hours of data for each.

United States: the Environmental Protection Agency (EPA) sets the AQI in federal rules (40 CFR Part 58, Appendix G) and explains it in a Technical Assistance Document (latest edition May 2026). It covers five pollutants: ozone, particle pollution (PM2.5 and PM10), carbon monoxide, sulphur dioxide and nitrogen dioxide, in six categories from Good to Hazardous. Gases are in ppb or ppm, readings are truncated before use, and NO₂ and SO₂ use the highest 1-hour value of the day.

What is changing: in 2024 the EPA lowered the PM2.5 breakpoint between Good and Moderate from 12.0 to 9.0 µg/m³ and merged its two Hazardous ranges. The D.C. Circuit refused to strike down the 2024 PM2.5 standard; the EPA now calls it unlawful, and states, industry and the US government have asked the Supreme Court to review it (EPA, 2 Oct 2026), so the PM2.5 breakpoints may change. In India, CPCB said in November 2026 that it is reviewing parts of its 2015 method, including hourly particle readings above 999 µg/m³, which are now left out; the index stays capped at 500. India’s 2009 air quality standards are also due for revision after an IIT Kanpur review. This tool follows the methods in force in November 2026.

What this tool leaves out: real-time “NowCast” values, data validation, averaging across several monitoring stations, and daily forecasts. India’s Severe range has no published upper concentration, so the tool uses a stated assumption there.

How this is calculated

Both methods use the same straight-line rule within each range: index = lower index + (reading − lower concentration) × (index width ÷ concentration width). The AQI is the highest pollutant index, rounded to a whole number. Worked numbers use the sample day.

StepRuleWorked exampleSource
India sub-indexFind the CPCB concentration range that holds the reading; interpolate within the matching index rangePM2.5 142 µg/m³ is in 121–250 (index 301–400): 301 + (142 − 121) × 99 ÷ 129 = 317CPCB, About National Air Quality Index
India averaging times24-hour averages for PM10, PM2.5, NO₂, SO₂, NH₃ and lead; 8-hour for CO (mg/m³) and ozoneCO 1.9 mg/m³ is in 1.1–2.0 (index 51–100): 95CPCB, About National Air Quality Index
India data rulesAt least 3 pollutants, one of them PM2.5 or PM10; at least 16 hours of data each; city bulletins average the stationsSample: 7 pollutants, PM2.5 and PM10 present, so there is enough data for an indexCPCB and MPPCB guidance; CPCB daily bulletin
India Severe range (assumption)CPCB publishes only “above” the Very poor range (for example 430+ for PM10). This tool stretches Severe over the width of the Very poor range and stops at 500PM10 470: 401 + (470 − 430) × 99 ÷ 79 = 451. Illustrative convention for learning, not a CPCB figureCPCB caps the index at 500 (statement, Nov 2026)
US truncationOzone 3 decimals (ppm); PM2.5 and CO 1 decimal; PM10, SO₂ and NO₂ whole numbers. Cut digits off, do not roundPM2.5 142 → 142.0 µg/m³ in 125.5–225.4 (201–300): 201 + 16.5 × 99 ÷ 99.9 = 217EPA Technical Assistance Document (May 2026)
US special rulesOzone: 8-hour values define up to 300; 1-hour values count from 0.125 ppm and the higher index is used. SO₂: highest 1-hour value below 305 ppb; 24-hour average at 305 ppb or more; above 500 the last row is extendedEPA example: 8-hour ozone 0.07853 ppm → 0.078 → 12640 CFR Part 58 Appendix G; EPA TAD
Unit conversionppb = µg/m³ × 24.45 ÷ molecular weight (25 °C, 1 atmosphere). NO₂ 46.01, SO₂ 64.07, O₃ 48.00, CO 28.01 g/mol; CO ppm = mg/m³ × 24.45 ÷ 28.01NO₂ 180 µg/m³ = 95.6 ppb → 95 → index 9540 CFR 50.3 reference conditions
CategoriesIndia: Good 0–50, Satisfactory 51–100, Moderate 101–200, Poor 201–300, Very poor 301–400, Severe 401–500. US: Good 0–50, Moderate 51–100, Unhealthy for Sensitive Groups 101–150, Unhealthy 151–200, Very Unhealthy 201–300, Hazardous 301+Sample: India 317 Very poor; US 217 Very UnhealthyCPCB; EPA TAD Table 1
Graded case

Prove you can apply it

Work out one day’s air quality index for a fictional city with both India’s CPCB method and the US EPA method, including unit conversion and truncation.

  • New numbers on every attempt
  • Answers checked against a tolerance
  • Up to 10 attempts a day, all free
Start the graded case
Verified learning credential US$10 ₹999 in India Public verification page, PDF with QR code, and a LinkedIn add. Pay only after you pass. A learning credential, not a professional certification.

Sources and rules used

Checked against the sources below in November 2026. Rules change: always use the official text for real work.

Questions about this tool

How is the AQI calculated?

Each pollutant’s reading is placed in a concentration range and turned into a sub-index by a straight-line rule within that range. The highest sub-index is the AQI, and that pollutant is the main (prominent) pollutant. India and the US use the same idea with different ranges.

Why is India’s AQI higher than the US AQI for the same air?

They are different scales. India’s index of 100 sits at its 24-hour PM2.5 standard of 60 µg/m³, while the US index of 100 sits at 35.4 µg/m³, and the upper ranges are drawn differently. On very polluted days India’s number is often higher, while on moderately polluted days the US category is often worse. Compare categories and health advice, not raw numbers.

Why does India’s AQI stop at 500?

CPCB designed the National AQI as a 0 to 500 scale. Above 500 the day stays “Severe”, because a larger number would not change the health category. In November 2026 CPCB said it is reviewing how very high particle readings are handled.

What does “truncate” mean in the US AQI?

Extra digits are cut off, not rounded. A PM2.5 reading of 35.47 µg/m³ becomes 35.4, ozone of 0.07853 ppm becomes 0.078. Only the final index is rounded to a whole number.

Did the US AQI change recently?

Yes. From 6 May 2024 the line between Good and Moderate for PM2.5 moved from 12.0 to 9.0 µg/m³, and the upper PM2.5 ranges were redrawn. The D.C. Circuit refused to strike down the 2024 PM2.5 standard; the EPA now calls it unlawful, and states, industry and the US government have asked the Supreme Court to review it (EPA, 2 Oct 2026), so the PM2.5 breakpoints may change.

Do I need an account?

No. You need a free account only to save results or take the graded case.

Can I use this tool for my company’s reporting?

No. The Playground is for learning only. It simplifies the official methods and uses sample data, so its results must not be used for business decisions, regulatory filings, assurance or investment. Use the official standard and qualified advice for real work.